{"product_id":"365n-v-automatic-liquid-shut-off-vessel","title":"365N-V Automatic Liquid Shut-Off Vessel","description":"\u003ch3 class=\"PDq2pG_selectionAnchorContainer\"\u003e365N-V Automatic Liquid Shut-Off Vessel – 1\/2\" NPT\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe Headline Filters 365N-V Automatic Liquid Shut-Off Vessel is designed to protect gas analysers, sample conditioning systems and other sensitive downstream instrumentation from unexpected liquid carryover.\u003c\/p\u003e\n\u003cp\u003eThe vessel captures \u003cstrong\u003eslugs of water or condensate\u003c\/strong\u003e entering the process or sample line before they can reach expensive downstream equipment.\u003c\/p\u003e\n\u003cp\u003eAs liquid collects inside the transparent nylon bowl, the internal PVC float mechanism rises with the liquid level. When the collected liquid reaches the shut-off level, the float-operated cone automatically closes the outlet flow path, stopping further flow downstream and helping prevent liquid from passing into the analyser or instrumentation.\u003c\/p\u003e\n\u003cp\u003eOnce the source of the liquid ingress has been identified, the collected liquid can be removed using the manual brass drain at the base of the bowl.\u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic liquid shut-off protection\u003c\/li\u003e\n\u003cli\u003eHelps protect analysers and instrumentation from liquid carryover\u003c\/li\u003e\n\u003cli\u003e1\/2\" NPT process connections\u003c\/li\u003e\n\u003cli\u003eAluminium head\u003c\/li\u003e\n\u003cli\u003eTransparent nylon bowl for visual inspection\u003c\/li\u003e\n\u003cli\u003ePVC float and shut-off cone mechanism\u003c\/li\u003e\n\u003cli\u003eManual brass drain\u003c\/li\u003e\n\u003cli\u003eFully mechanical operation\u003c\/li\u003e\n\u003cli\u003eNo electrical supply or external control system required\u003c\/li\u003e\n\u003cli\u003eSuitable for gas and analyser sample conditioning applications\u003c\/li\u003e\n\u003cli\u003eDesigned to provide protection against unexpected slugs of water or condensate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eHow It Works\u003c\/h5\u003e\n\u003cp\u003eDuring normal operation, gas flows through the 365N-V while the internal float remains in its lower position.\u003c\/p\u003e\n\u003cp\u003eIf water or condensate enters the line, it collects within the nylon bowl.\u003c\/p\u003e\n\u003cp\u003eAs the liquid level rises, the PVC float rises with it. When the liquid reaches the predetermined shut-off level, the float-operated cone closes the outlet and stops downstream flow before the collected liquid can pass out of the vessel.\u003c\/p\u003e\n\u003cp\u003eThe bowl can then be manually drained before the system is returned to normal operation.\u003c\/p\u003e\n\u003ch5\u003eTypical Applications\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eGas analyser protection\u003c\/li\u003e\n\u003cli\u003eProcess analyser sample conditioning\u003c\/li\u003e\n\u003cli\u003eContinuous Emissions Monitoring Systems (CEMS)\u003c\/li\u003e\n\u003cli\u003eEmissions analyser systems\u003c\/li\u003e\n\u003cli\u003eInstrumentation protection\u003c\/li\u003e\n\u003cli\u003eGas sampling systems\u003c\/li\u003e\n\u003cli\u003eCondensate protection\u003c\/li\u003e\n\u003cli\u003eMoisture removal systems\u003c\/li\u003e\n\u003cli\u003eProcess and laboratory gas systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eConstruction\u003c\/h5\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eComponent\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e365N-V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHead\u003c\/td\u003e\n\u003ctd\u003eAluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBowl\u003c\/td\u003e\n\u003ctd\u003eNylon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloat mechanism\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain\u003c\/td\u003e\n\u003ctd\u003eBrass, manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections\u003c\/td\u003e\n\u003ctd\u003e1\/2\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eProtecting Sensitive Downstream Equipment\u003c\/h5\u003e\n\u003cp\u003eUnexpected condensate or a sudden slug of water can cause contamination, measurement errors or damage to sensitive analyser equipment.\u003c\/p\u003e\n\u003cp\u003eAlthough filters and separators can remove normal levels of entrained liquid, a larger volume of liquid can overwhelm a conventional sample conditioning system.\u003c\/p\u003e\n\u003cp\u003eThe 365N-V Automatic Liquid Shut-Off Vessel provides an additional layer of protection by mechanically shutting off downstream flow when the liquid reaches the shut-off level, helping prevent liquid breakthrough and protecting valuable analyser and instrumentation equipment.\u003c\/p\u003e\n\u003ch5\u003eProduct Summary\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHeadline Filters 365N-V Automatic Liquid Shut-Off Vessel with 1\/2\" NPT connections. Designed to capture water and condensate from gas or sample lines and automatically stop downstream flow when the internal float reaches its shut-off level, protecting analysers and sensitive instrumentation from liquid carryover.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Headline Filters","offers":[{"title":"Default Title","offer_id":56222484595073,"sku":"23650040","price":60.0,"currency_code":"GBP","in_stock":true}],"url":"https:\/\/headlinefilters.com\/products\/365n-v-automatic-liquid-shut-off-vessel","provider":"Headline Filters","version":"1.0","type":"link"}